MV-VIEW-01 CatalogueVIEW-02 Station commissioningVIEW-03 SDK & driver compatibilityVIEW-04 Capture & evidenceVIEW-05 Trigger & capture groupsVIEW-06 CalibrationVIEW-07 Source contract & mappingVIEW-08 Inspection & provenanceVIEW-09 Vision / WMS / LocateLinkVIEW-10 Fault & recovery labVIEW-11 Qualification & coverageVIEW-12 Release & rollbackEyeZ job catalogue (60)Software & standards (16)Primary sources (54)Import checks
Acting asAuthorization is evaluated by effect, not by screen. Demonstration only.0 session operations
Primary source register
A reviewed source establishes what the vendor states publicly. It does not establish vendor wire formats, native behaviour or runtime support, and no source document is reproduced here.
Synthetic vision workspace. No camera, frame grabber or vision controller has been contacted; camera SDKs run only in engineering-managed edge workers, never in a browser. No real image exists here — every frame is a described placeholder. Nothing is live or qualified, and no inspection result releases product or causes any robot, reject, dispatch or stock effect.
Sources (54)
| Source | Title | Evidence scope limitation | Access state | Reviewed |
|---|---|---|---|---|
| MV-S01 | Basler pylon Software Suite | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S02 | JAI software and SDK selection | eBUS SDK for JAI; legacy JAI SDK unsupported since 2020. Camera Link/CoaXPress paths depend on the acquisition board. | reviewed | 2026-09-22 |
| MV-S03 | JAI eBUS licensing for other vendors | JAI bundle licensing is not universal permission to distribute/use other-vendor cameras. | reviewed | 2026-09-22 |
| MV-S04 | Teledyne FLIR machine-vision SDK selection | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S05 | Teledyne FLIR PySpin API | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S06 | Teledyne DALSA Sapera Vision software | Vendor announcement establishes Sapera acquisition/processing scope; current LT versus processing package, OS and version require pinning. | reviewed | 2026-09-22 |
| MV-S07 | Allied Vision Vimba X | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S08 | IDS peak | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S09 | Baumer neoAPI | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S10 | LUCID Arena SDK | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S11 | Hikrobot MVS downloads | MVS package and native API details must be obtained from vendor. Download surface could not be retrieved; no native method signature asserted. | access_unavailable | 2026-09-22 |
| MV-S12 | Daheng Galaxy downloads | Current vendor page distinguishes Windows, Linux-x86, ARM and Android packages and model/interface coverage; Linux bundle includes Python installer. | reviewed | 2026-09-22 |
| MV-S13 | XIMEA APIs | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S14 | OMRON Sentech downloads | Vendor download request form retrieved. Exact Sentech SDK/StApi package, version, supported bindings and models must be supplied. | registration_required | 2026-09-22 |
| MV-S15 | Vieworks SDK and documentation downloads | Exact SDK, transport and board-dependent package to be pinned from vendor portal; not inferred from another vendor. | registration_required | 2026-09-22 |
| MV-S16 | Emergent eSDK developer guide | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S17 | Ensenso SDK components / NxLib | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S18 | Zivid SDK | GPU/driver compatibility is a deployment prerequisite to verify, not a CPU-only IPC default. | reviewed | 2026-09-22 |
| MV-S19 | Photoneo acquisition software | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S20 | Photoneo PhoXi Control 1.17 | 2026 vendor release documents Python API in addition to C++/C#; do not carry old no-Python assumption. | reviewed | 2026-09-22 |
| MV-S21 | LMI support: Classic versus GoPxL | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S22 | SICK Ranger3 Python examples | Vendor repository: GenIStream has no Python API; Python examples use Harvesters with the SICK GenTL producer. | reviewed | 2026-09-22 |
| MV-S23 | RealSense librealsense | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S24 | Orbbec SDK | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S25 | Stereolabs ZED CUDA requirement | ZED SDK depth processing requires CUDA. Raw open capture is not equivalent to SDK depth. | reviewed | 2026-09-22 |
| MV-S26 | FLIR Atlas SDK | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S27 | Optris OTC SDK | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S28 | Specim software: Lumo and INSIGHT | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S29 | Prophesee OpenEB | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S30 | Prophesee developer access and licensing | OpenEB and commercial Metavision modules have different entitlements; do not redistribute proprietary modules. | reviewed | 2026-09-22 |
| MV-S31 | Cognex In-Sight SDK documentation | Classic SDK and Web SDK are separate generation-dependent interfaces; download/edition entitlements require pinning. | reviewed | 2026-09-22 |
| MV-S32 | KEYENCE CV-X communication and ActiveX manuals | Result communications / ActiveX tools are not a universal native camera acquisition SDK. | reviewed | 2026-09-22 |
| MV-S33 | SICK AppSpace machine vision | InspectorP/AppSpace capability surface reviewed; exact installed app API/export contract required. | reviewed | 2026-09-22 |
| MV-S34 | Zebra machine-vision software | Aurora Focus smart-camera configuration and Aurora Imaging Library processing are separate layers. | reviewed | 2026-09-22 |
| MV-S35 | Axis VAPIX developer reference | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S36 | ifm ifm3d SDK | O3R is principal target; current repository labels O3D/O3X support experimental. Not the same interface as generic ifm IoT Core. | reviewed | 2026-09-22 |
| MV-S37 | IMPACT vision software and SDK | Current product surface describes .NET/C# SDK and supported Datalogic vision devices; installed generation to be verified. | reviewed | 2026-09-22 |
| MV-S38 | EMVA GenICam modules | GenApi/GenTL/SFNC/PFNC/GenDC define different layers; conformance alone is not end-to-end qualification. | reviewed | 2026-09-22 |
| MV-S39 | Euresys eGrabber | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S40 | MVTec image acquisition interfaces | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S41 | Common Vision Blox SDK documentation | Versioned technical reference; exact newer release and modules must be selected explicitly. | reviewed | 2026-09-22 |
| MV-S42 | Zebra Aurora Imaging Library | Former MIL product lineage; distinct from Aurora Focus and Aurora Vision Library. | reviewed | 2026-09-22 |
| MV-S43 | Hikrobot VisionMaster | Processing/configuration platform and secondary-development interfaces; distinct from MVS acquisition. | reviewed | 2026-09-22 |
| MV-S44 | OpenCV licensing | OpenCV 4.5+ Apache 2.0; older distributions differ. Audit third-party modules separately. | reviewed | 2026-09-22 |
| MV-S45 | OpenVINO CPU device | Versioned CPU capability reference only; select supported release and benchmark actual model/CPU. | reviewed | 2026-09-22 |
| MV-S46 | ONNX Runtime execution providers | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S47 | Ultralytics licensing | Vendor publishes AGPL and Enterprise alternatives. Deployment requires organization-approved license review, including model and export rights. | reviewed | 2026-09-22 |
| MV-S48 | Cognex industrial defect applications | Application examples inform candidate jobs, not achieved Optimon accuracy or deployed capability. | reviewed | 2026-09-22 |
| MV-S49 | Cognex automotive applications | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S50 | Cognex OCR applications | Primary vendor/standards documentation reviewed; exact package and target hardware require qualification. | reviewed | 2026-09-22 |
| MV-S51 | Cognex VisionPro programming reference | Versioned VisionPro programming reference; current selected package/OS/runtime license require verification. | reviewed | 2026-09-22 |
| MV-S52 | NI Vision driver compatibility | Device/driver layer reviewed; release-specific binding support must be checked. | reviewed | 2026-09-22 |
| MV-S53 | NI Vision Acquisition 2023 Q1 release notes | HTML release notes state bundled .NET support removed since VAS 19.0; do not infer current binding support from the generic compatibility overview. | reviewed | 2026-09-22 |