MV-VIEW-01 CatalogueVIEW-02 Station commissioningVIEW-03 SDK & driver compatibilityVIEW-04 Capture & evidenceVIEW-05 Trigger & capture groupsVIEW-06 CalibrationVIEW-07 Source contract & mappingVIEW-08 Inspection & provenanceVIEW-09 Vision / WMS / LocateLinkVIEW-10 Fault & recovery labVIEW-11 Qualification & coverageVIEW-12 Release & rollbackEyeZ job catalogue (60)Software & standards (16)Primary sources (54)Import checks
Acting asAuthorization is evaluated by effect, not by screen. Demonstration only.0 session operations
MV-VIEW-11
Qualification and coverage ledger
within /coresync/build/adapters · QA/release ownerPer profile and use case: specification, UI, application logic, native adapter, operating envelope and qualification evidence.
Guardrail · Test existence is not test success; no universal accuracy/latency target or market-share ranking.
Profiles with UI exercised
33 passed
Application logic exercised
33 passed
Native adapter conformance
33 blocked
Source-version qualification
33 not run
Qualification ledger (33)
| Profile | Connector | UI | App logic | Native adapter | Environmental | Candidate jobs | Stated limitation |
|---|---|---|---|---|---|---|---|
| MV-CAM-001 Basler pylon camera families | CS-CON-0051 | passed | passed | blocked | not_run | 42 | Preserve existing CS-CON-0051; pin model/interface and SDK bindings. pylon does not itself supply domain defect semantics. |
| MV-CAM-002 JAI GigE/USB3 and prism/line-scan camera profiles | CS-CON-0275 | passed | passed | blocked | not_run | 24 | Legacy JAI SDK is unsupported; qualify RGB registration, channel order and selected transport. JAI bundle licensing does not cover arbitrary vendors. |
| MV-CAM-003 Teledyne FLIR GenICam machine-vision cameras | CS-CON-0276 | passed | passed | blocked | not_run | 0 | Not FLIR Atlas thermal SDK. Legacy FlyCapture devices need separate compatibility treatment. |
| MV-CAM-004 Teledyne DALSA Area/line-scan cameras and acquisition boards | CS-CON-0277 | passed | passed | blocked | not_run | 12 | Separate Sapera LT acquisition from Sapera processing licenses; frame-grabber firmware and tap geometry are dependencies. |
| MV-CAM-005 Allied Vision Vimba X supported cameras | CS-CON-0278 | passed | passed | blocked | not_run | 12 | Use official camera/interface/version matrix; do not apply vendor-wide support automatically. |
| MV-CAM-006 IDS uEye camera families | CS-CON-0279 | passed | passed | blocked | not_run | 12 | Ensenso uses NxLib instead; legacy UI devices require an explicitly supported transport layer. |
| MV-CAM-007 Baumer neoAPI-compatible industrial cameras | CS-CON-0280 | passed | passed | blocked | not_run | 6 | Confirm camera/firmware and Windows/Linux/ARM package matrix before live activation. |
| MV-CAM-008 LUCID Vision Labs Arena-supported GigE cameras | CS-CON-0281 | passed | passed | blocked | not_run | 18 | Separate intensity, depth and polarization pixel layouts; device features remain model-specific. |
| MV-CAM-009 Hikrobot MVS-supported industrial cameras | CS-CON-0282 | passed | passed | blocked | not_run | 0 | MVS download/API details were not retrievable. VisionMaster is a processing platform, not evidence of every MVS acquisition function. |
| MV-CAM-010 Daheng Imaging MERCURY/MARS/VENUS and supported boards | CS-CON-0283 | passed | passed | blocked | not_run | 6 | Windows/Linux-x86/ARM/Android packages expose different model and interface matrices; pin them rather than treating all as equivalent. |
| MV-CAM-011 XIMEA xiAPI-supported cameras | CS-CON-0284 | passed | passed | blocked | not_run | 6 | Camera handle ownership, bandwidth, feature availability and SDK model coverage must be explicit. |
| MV-CAM-012 OMRON Sentech GigE/USB3 and other industrial cameras | CS-CON-0285 | passed | passed | blocked | not_run | 0 | Registration-gated download; validate package name, language bindings, model/interface and OS against supplied documents. |
| MV-CAM-013 Vieworks Area/line-scan industrial cameras | CS-CON-0286 | passed | passed | blocked | not_run | 0 | Do not substitute a different vendor SDK merely because a camera supports GenICam. Pin acquisition-board and tap geometry requirements. |
| MV-CAM-014 Emergent Vision Technologies eSDK-compatible high-speed cameras | CS-CON-0287 | passed | passed | blocked | not_run | 12 | NIC, receive buffering, zero-copy path and sustained bandwidth require measurement; Pro features and GPU dependencies are not baseline assumptions. |
| MV-CAM-015 Ensenso / IDS Ensenso stereo camera families | CS-CON-0288 | passed | passed | blocked | not_run | 12 | Pin calibration, workspace, occlusion behavior and coordinate frames; do not reuse IDS peak as equivalent SDK. |
| MV-CAM-016 Zivid Zivid 3D cameras | CS-CON-0289 | passed | passed | blocked | not_run | 12 | Qualify supported GPU/OpenCL/driver and OS. Not eligible for an unmodified CPU-only IPC assumption. |
| MV-CAM-017 Photoneo PhoXi and MotionCam-3D | CS-CON-0290 | passed | passed | blocked | not_run | 6 | Python support is release-dependent. Static versus motion acquisition and GigE alternative paths are separately qualified. |
| MV-CAM-018 LMI Technologies Gocator Classic / GoPxL | CS-CON-0291 | passed | passed | blocked | not_run | 18 | Classic GoSDK and GoPxL are not interchangeable; pin exact scanner, firmware, result and profile protocols. |
| MV-CAM-019 SICK Ranger3 / Ruler3 | CS-CON-0292 | passed | passed | blocked | not_run | 6 | Do not claim a native GenIStream Python API. Preserve encoder position, profile ordering, calibration and missing lines. |
| MV-CAM-020 RealSense librealsense-supported depth devices | CS-CON-0293 | passed | passed | blocked | not_run | 12 | List stable versus experimental models explicitly; calibration, firmware, depth scale and host support are required. |
| MV-CAM-021 Orbbec SDK-supported depth camera families | CS-CON-0294 | passed | passed | blocked | not_run | 6 | Old OpenNI device support is not inherited from SDK v2; pin device/model package matrix. |
| MV-CAM-022 Stereolabs ZED camera families | CS-CON-0295 | passed | passed | blocked | not_run | 6 | Raw camera capture without CUDA is not equivalent to ZED SDK depth. Keep optional and unavailable on baseline CPU-only hosts. |
| MV-CAM-023 Teledyne FLIR Radiometric thermal cameras | CS-CON-0296 | passed | passed | blocked | not_run | 12 | Spinnaker is not a substitute. Require radiometric access, emissivity/reflection/transmission settings and camera calibration applicability. |
| MV-CAM-024 Optris PI/Xi thermal camera profiles | CS-CON-0297 | passed | passed | blocked | not_run | 6 | Use current OTC package; archived Direct SDK is a separate compatibility path. Qualify temperature data rather than palette images alone. |
| MV-CAM-025 Specim Hyperspectral camera families | CS-CON-0298 | passed | passed | blocked | not_run | 12 | Preserve wavelength calibration, white/dark references, exposure and conveyor geometry. INSIGHT is analysis software, not the camera driver. |
| MV-CAM-026 Prophesee Supported event-based sensors / EVKs | CS-CON-0299 | passed | passed | blocked | not_run | 12 | Native events are not conventional video frames. OpenEB and commercial Metavision modules have different licensing and hardware coverage. |
| MV-CAM-027 Cognex In-Sight smart-camera families | CS-CON-0049 | passed | passed | blocked | not_run | 18 | Preserve CS-CON-0049. Result job/recipe/version and image transfer depend on device generation; not unrestricted raw sensor access. |
| MV-CAM-028 KEYENCE CV-X vision controllers | CS-CON-0300 | passed | passed | blocked | not_run | 6 | Do not invent a universal camera SDK. Image access, result IDs, control and operating-system compatibility require installed-system contract. |
| MV-CAM-029 SICK InspectorP / AppSpace | CS-CON-0301 | passed | passed | blocked | not_run | 0 | Installed app defines result schema and capabilities. Generic SOPAS/CoLa does not establish complete inspection support. |
| MV-CAM-030 Zebra VS smart-camera families | CS-CON-0302 | passed | passed | blocked | not_run | 6 | Aurora Focus is not Aurora Imaging Library. Actual result protocol and image retrieval require model/firmware qualification. |
| MV-CAM-031 Axis VAPIX-compatible network cameras | CS-CON-0052 | passed | passed | blocked | not_run | 12 | Preserve CS-CON-0052. Surveillance video is not automatically calibrated metrology; privacy and stream-loss behavior must be specified. |
| MV-CAM-032 ifm O3R vision platform | CS-CON-0303 | passed | passed | blocked | not_run | 18 | O3D/O3X support is marked experimental in current repository; do not broaden O3R qualification to those devices or to generic IoT Core. |
| MV-CAM-033 Datalogic / IMPACT ecosystem Supported P2/P3x vision devices | CS-CON-0304 | passed | passed | blocked | not_run | 6 | Pin hardware and installed IMPACT generation. A mobile barcode scanner SDK is not a machine-vision controller SDK. |
Coverage — stated honestly
- 60 of 60 EyeZ jobs name at least one candidate camera profile. A candidate reference is a design suggestion, not coverage and not an implemented capability.
- The 192 CoreSync job denominator is unchanged by this extension. The 60 EyeZ jobs specialize or compose existing capabilities and are counted separately.
- Catalogue presence never implies runtime support. No native adapter here has been contacted, no vendor wire format has been observed and no source version has been qualified.
- User interface, application logic, native adapter conformance and environmental qualification are four separate states and are never collapsed into one green badge.