CX-02
BACnet
Interface operations, auth, source semantics, version/edition support, shared driver relationships, documentation, gaps and ownership.
Acceptance · Show technical reference grade separately from implementation and environment qualification. Operations getConnectorManifest
CS-CON-0006BACnetF01 · Industrial open protocolsT01SURFACEstatus: proposed_targetqualification: not_run
CX-02 ProfileCX-03 Configure connectionCX-08 Source contractCX-11 LaboratoryCX-12 EvidenceCX-14 Qualification
Synthetic connector workspace. Every profile here is a proposed target. Nothing on this screen is a live, qualified or certified adapter, no payload is a captured vendor wire message, and the simulation engine has no code path to a real endpoint.
Profile
Source surface
ReadProperty/ReadPropertyMultiple; COV subscription; trend-log reads where supported
Engine
bacnet
Authentication
Network segmentation; BACnet/SC certificates when supported
Incremental and recovery
COV renewal and trend-log sequence; poll fallback with explicit gaps
Constraints
Bound Who-Is discovery; confirm object/property services; MS/TP needs local serial/gateway adapter.
Implementation kind
standard_protocol_profile
Runtime placement options
plant, edge
Documentation
What is known, and how well
Source-evidence grade — SURFACE
Interface draft — verify operations
Reviewer note
Product/API surface identified. Some references are portal/index pages or were not fully retrievable. Authentication, pagination, field coverage and version-specific behavior need operation-level confirmation.
Vendor wire schema
not_embedded; pin licensed/OpenAPI/WSDL/device spec at qualification
Native sample
synthetic post-decoder fixture only; not a captured vendor wire payload
Runtime implementation
unassessed_existing_or_not_built
Qualification
not_run
Selection basis
Industrial relevance and broad source-system coverage; not a measured popularity ranking (reference 2026-09-22)
Evidence grade describes the public technical reference material only. It is not implementation status and not qualification in any environment.
Live-activation gates — 0 of 5 satisfied
live activation blocked| Live-activation gate | State | Basis |
|---|---|---|
| Authorized access proven at the source | not satisfied | No connection configured. |
| Source edition / version pinned | not satisfied | Edition not pinned. |
| Approved native source schema | not satisfied | Vendor wire schema status: not_embedded; pin licensed/OpenAPI/WSDL/device spec at qualification. |
| Signed runtime package | not satisfied | Runtime implementation: unassessed_existing_or_not_built. |
| Qualification evidence in this environment | not satisfied | Qualification: not_run. |
Block until exact provider version, native schema, authorization, adapter package and environment qualification evidence are present.
Shared template T01 · Industrial telemetry
Canonical entity
MeasurementObserved
Wire shape
sdk_record
Resources
process_temperature, motor_current, device_status
Natural keys
sourceTag, sourceTime
Time field
sourceTime
Modelled failures
wrong_unit, source_restart, offline, duplicate
Template field shape
{
"sourceTag": "string",
"value": "number",
"unit": "string",
"sourceTime": "date-time",
"providerQuality": "string"
}Configuration, packaging and acceptance
Configuration schema
catalogue/config-schemas/CS-CON-0006.schema.json
Source contract
Package requirements
Version-pinned adapter and transitive dependencies; SBOM and third-party redistribution/license review; Configuration + native source schemas; Connection/discovery/read/recovery tests; Locality and secret-binding enforcement; Reference mapping templates with approval gates; Operating limits and upgrade/rollback guide
Specific configuration
- network_type
- device_instance
- network_number
- object_ids
- property_ids
- cov_lifetime_s
- sc_hub_url
Acceptance tests
| CS-CON-0006-AT-01 | Connect and discover only authorized resources; reject unauthorized identity | not_run |
| CS-CON-0006-AT-02 | Read declared source surface and preserve original key/time/quality | not_run |
| CS-CON-0006-AT-03 | Resume according to profile cursor; retention loss explicitly reported | not_run |
| CS-CON-0006-AT-04 | Duplicate/revision and partial-result behavior matches declared contract | not_run |
| CS-CON-0006-AT-05 | Contract drift quarantined; no secret leakage or source control side effects | not_run |
| CS-CON-0006-AT-06 | Qualify against exact source constraints: Bound Who-Is discovery; confirm object/property services; MS/TP needs local serial/gateway adapter. | not_run |
Canonical output and use-case reference
Canonical output candidates
MeasurementObserved
Canonical contract policy
Candidate envelope family only. Approve source-specific bindings through the canonical authority; no business vocabulary in the driver.
Referenced use-case families
OT, CON, DIS, SRC, MAP, DQ, REC, SEC, CFG, VAL
Exact use-case mapping
unassessed — family-level reference only. It does not claim any of the 192 use cases as covered. Open CX-16 coverage
Simulation scenarios declared for this profile
Happy pathAuthentication expiredNative schema driftDuplicate deliveryUnit mismatchSource restartRuntime offline
Connections configured against this profile
None yet. Configure a simulated connection (CX-03).
Other profiles in F01
CS-CON-0001OPC UACS-CON-0002OPC Classic DA/HDA/AECS-CON-0003Modbus TCP and RTUCS-CON-0004MQTT with Sparkplug B profileCS-CON-0005EtherNet/IP CIP explicit messagingCS-CON-0007KNXnet/IPCS-CON-0008M-Bus and wireless M-BusCS-CON-0009DNP3CS-CON-0010IEC 60870-5-104CS-CON-0011IEC 61850 MMSCS-CON-0012MTConnect
Profiles sharing this engine
No other profile uses this engine.