CoreSync Connectors
Connect Optimon to the machines, systems and data you already run.
Showing 13 of 205 connectors
Guided demoPLCs & Controllers (13)
Allen-Bradley Micro800
Rockwell Automation (Allen-Bradley)
- Covers:
- Micro820 / Micro830 / Micro850 / Micro870
- Protocol / API:
- EtherNet/IP CIP (global variables)
Reads Micro800 global variables over EtherNet/IP CIP.
Allen-Bradley MicroLogix / SLC 500 / PLC-5 (PCCC)
Rockwell Automation (Allen-Bradley)
- Covers:
- MicroLogix, SLC 500, PLC-5
- Protocol / API:
- PCCC over EtherNet/IP; DF1 full-duplex serial
Reads legacy Allen-Bradley data files over PCCC (EtherNet/IP) or DF1 serial.
Beckhoff TwinCAT 3 (ADS)
Beckhoff Automation
- Covers:
- TwinCAT 3 PLC runtimes
- Protocol / API:
- ADS over AMS/TCP
Reads TwinCAT 3 PLC symbols (GVL / program variables) via ADS sum reads, PLC state.
Delta DVP / AS / AH500 PLCs (Modbus TCP)
Delta Electronics
- Covers:
- DVP, AS and AH500 series (address profiles)
- Protocol / API:
- Modbus TCP with Delta address profiles
Reads Delta PLC devices (D, M, X, Y, ...) over Modbus TCP using the DVP or AS/AH address map.
KEYENCE KV Host Link
KEYENCE
- Covers:
- KV-8000, KV-7500, KV-5500, KV-5000
- Protocol / API:
- KV Host Link (upper link), ASCII over TCP
Reads KV-series device memory over the KV Host Link protocol.
Mitsubishi Electric MELSEC (SLMP)
Mitsubishi Electric
- Covers:
- MELSEC iQ-R, iQ-F, Q, L series
- Protocol / API:
- SLMP (MC protocol 3E binary frame)
Reads MELSEC PLC bit and word devices via SLMP.
Mitsubishi Electric MELSEC FX (MC protocol 1E)
Mitsubishi Electric
- Covers:
- MELSEC FX3U / FX3G / FX3S with FX3U-ENET-ADP
- Protocol / API:
- MC protocol 1E frame
Reads FX-series bit and word devices over the MC protocol 1E frame.
Omron FINS
OMRON
- Covers:
- CS / CJ / CP series and NJ / NX (FINS server)
- Protocol / API:
- FINS/TCP and FINS/UDP
Reads Omron PLC memory areas over FINS/TCP or FINS/UDP.
Omron NJ / NX (EtherNet/IP)
OMRON
- Covers:
- NJ / NX machine controllers (and NY industrial PCs)
- Protocol / API:
- EtherNet/IP CIP (symbolic variables)
Reads published NJ/NX symbolic variables over EtherNet/IP CIP.
Rockwell ControlLogix / CompactLogix
Rockwell Automation (Allen-Bradley)
- Covers:
- ControlLogix, CompactLogix (Logix 5000 controllers)
- Protocol / API:
- EtherNet/IP CIP
Reads ControlLogix / CompactLogix tags via EtherNet/IP CIP.
Rockwell FactoryTalk Linx Gateway (OPC UA)
Rockwell Automation
- Covers:
- FactoryTalk Linx Gateway (Logix tags via device shortcuts)
- Protocol / API:
- OPC UA
Reads Logix controller and program tags through FactoryTalk Linx Gateway's OPC UA server.
Siemens SIMATIC S7 (S7comm classic)
Siemens
- Covers:
- SIMATIC S7-300, S7-400, S7-1200, S7-1500 (PUT/GET)
- Protocol / API:
- S7comm over ISO-on-TCP (RFC 1006)
Reads S7 data blocks and memory areas over classic S7comm PUT/GET.
Siemens SIMATIC S7-1200 / S7-1500 (OPC UA)
Siemens
- Covers:
- SIMATIC S7-1200, S7-1500 (built-in OPC UA server)
- Protocol / API:
- OPC UA
Reads S7-1200 / S7-1500 PLC tags via the CPU's OPC UA server.
Don't see your system?
Tell us what you run and we'll show you how CoreSync connects to it.
Every connector is read-only. CoreSync reads from your systems and does not write back to them.